The BT-740 is an 8.4" multi-parameter patient monitor specifically designed for neonatal care. It provides essential monitoring capabilities for vital signs, ensuring accurate and reliable data for healthcare professionals in various clinical settings.
Key Features
- Display: 8.4" Color Touch LCD
-
Parameters Monitored:
- ECG (Electrocardiogram)
- Respiration Rate
- SpO2 (Oxygen Saturation)
- NIBP (Non-Invasive Blood Pressure)
- Temperature
- Optional: CO2, IBP (Invasive Blood Pressure), Multi-gas, Cardiac Output, Masimo SpO2
- Design: Fan-less design for quieter operation
Technical Specifications
Model
- Model Name: BT-740
Display
- Type: 8.4" Color Touch LCD
ECG Specifications
- Lead Type: 5 lead
- Gain Selection: x0.25, x0.5, x1, x2, x4, Auto
- Sweep Speed: 12.5, 25, 50 mm/s
-
Bandwidth:
- Diagnostic Mode: 0.5-130 Hz
- Monitoring Mode: 0.5-40 Hz
- Surgery Mode: 1-25 Hz
- Strong Mode: 5-20 Hz
-
Heart Rate Range:
- Adult: 15-300 bpm
- Pediatric/Neonate: 15-350 bpm
Respiration Specifications
- Method: Trans-thoracic Impedance
- Measurement Range: 0-120 rpm
- Sweep Speed: 6.25, 12.5, 25 mm/s
SpO2 Specifications
- Measurement Range: 0-100%
-
Accuracy:
- Adult/Pediatric: ±2% (70-100%)
- Neonate: ±3%
- (0-69%: Unspecified)
- Perfusion Index: 0.05-20%
- Pulse Rate Range: 25-250 bpm
NIBP Specifications
- Method: Automatic Oscillometric
- Operation Modes: Manual, Auto, STAT
-
Parameters Monitored:
-
Systolic Range:
- Adult: 40-270 mmHg
- Pediatric: 40-200 mmHg
- Neonate: 40-130 mmHg
-
Diastolic Range:
- Adult: 10-210 mmHg
- Pediatric: 10-160 mmHg
- Neonate: 10-100 mmHg
-
Mean Range:
- Adult: 20-230 mmHg
- Pediatric: 20-175 mmHg
- Neonate: 20-100 mmHg
-
Systolic Range:
Temperature Measurement
- Range: 0-50°C (41 to 122°F)
- Parameters: T1, T2, and TD
IBP Specifications
- Channel: 2 Channel / 4 Channel
- Range: -50 to 400 mmHg
Printer Specifications
- Type: Thermal dot array
- Print Speed: 12.5, 25, 50 mm/s
- Paper Size: 50 mm
CO2 Specifications
- Method: Masimo ISA / Bistos
- Multi-gas/O2 Method: Masimo ISA
- SpO2 Method: Masimo SpO2
Cardiac Output
- Method: Thermodilution
- Range: 0.2-20 L/min
Battery and Power Specifications
- Battery Type: Li-ion (4400 mAh)
- Run Time: Approximately 6 hours
- Charging Time: Approximately 4 hours
Connectivity
- PC Software Interface: RJ45, USB, Nursing call
Application Range
The BT-740 Patient Monitor for Neonatal is suitable for use in various clinical settings, including:
- Neonatal Intensive Care Units (NICU)
- Pediatric Wards
- Emergency Departments
- General Wards for neonatal patients
Wishlist
Wishlist is empty.
Wishlist
Compare
Shopping cart
Your cart is empty.
Return to shop