The BT-780 is a 15.6" multi-parameter patient monitor designed for comprehensive monitoring of vital signs. It is equipped with advanced features suitable for a variety of clinical environments, providing accurate and reliable data for patient care.
Key Features
-
Display: 15.6" Color Touch LCD
-
Parameters Monitored:
- ECG (Electrocardiogram)
- Respiration Rate
- SpO2 (Oxygen Saturation)
- NIBP (Non-Invasive Blood Pressure)
- Temperature
- Optional: CO2, IBP (Invasive Blood Pressure), Multi-gas, Cardiac Output, Masimo SpO2
-
Design: Ultra-slim design for enhanced portability
-
Battery Life: Over 5 hours of continuous use
Technical Specifications
Model
Display
-
Type: 15.6" Color Touch LCD
ECG Specifications
-
Lead Type: 3/5 lead
-
Gain Selection: x0.125, x0.25, x0.5, x1, x2, x4, Auto
-
Sweep Speed: 12.5, 25, 50 mm/s
-
Bandwidth:
-
Diagnostic Mode: 0.05-100 Hz
-
Monitoring Mode: 0.5-40 Hz
-
Surgery Mode: 1-25 Hz
-
Strong Mode: 5-20 Hz
-
Heart Rate Range:
- Adult: 15-300 bpm
- Pediatric/Neonate: 15-350 bpm
Respiration Specifications
-
Method: Trans-thoracic Impedance
-
Measurement Range: 0-120 rpm
-
Sweep Speed: 6.25, 12.5, 25 mm/s
SpO2 Specifications
-
Measurement Range: 0-100%
-
Accuracy:
- Adult/Pediatric: ±2% (70-100%)
- Neonate: ±3%
- (0-69%: Unspecified)
-
Perfusion Index: 0.05-20%
-
Pulse Rate Range: 25-250 bpm
NIBP Specifications
-
Method: Automatic Oscillometric
-
Operation Modes: Manual, Auto, STAT
-
Parameters Monitored:
-
Systolic Range:
- Adult: 30-280 mmHg
- Pediatric: 30-230 mmHg
- Neonate: 30-145 mmHg
-
Diastolic Range:
- Adult: 10-220 mmHg
- Pediatric: 10-165 mmHg
- Neonate: 10-105 mmHg
-
Mean Range:
- Adult: 10-240 mmHg
- Pediatric: 10-175 mmHg
- Neonate: 10-115 mmHg
Temperature Measurement
-
Range: 0-50°C (41 to 122°F)
-
Parameters: T1, T2, and TD
IBP Specifications
-
Channel: 2 Channel / 4 Channel
-
Range: -50 to 400 mmHg
Printer Specifications
-
Type: Thermal dot array
-
Print Speed: 12.5, 25, 50 mm/s
-
Paper Size: 50 mm
CO2 Specifications
-
Method: Masimo ISA / Bistos
-
Multi-gas/O2 Method: Masimo ISA
-
SpO2 Method: Masimo SpO2
Cardiac Output
-
Method: Thermodilution
-
Range: 0.2-20 L/min
Battery and Power Specifications
-
Battery Type: Li-ion (4400 mAh)
-
Run Time: Approximately 5 hours
-
Charging Time: Approximately 4 hours
Connectivity
-
PC Software Interface: RJ45, USB, Nursing call
Application Range
The BT-780 Patient Monitor is suitable for use in various clinical settings, including:
- Intensive Care Units (ICU)
- Operating Rooms
- Emergency Departments
- General Wards for adult, pediatric, and neonatal patients